20220326141712

2022 High quality Intermediate Of Allopurinol - ETHYL (ETHOXYMETHYLENE)CYANOACETATE with assay 98% min – MEVA

Hello, come to consult our products !

2022 High quality Intermediate Of Allopurinol - ETHYL (ETHOXYMETHYLENE)CYANOACETATE with assay 98% min – MEVA


Product Detail

Product Tags

Related Video

Feedback (2)

We have the most advanced production equipment, experienced and qualified engineers and workers, recognized quality control systems and a friendly professional sales team pre/after-sales support for Processing Agent For Fibers, Activated Carbon For Edible Oil Purification, Granular Activated Carbon, We sincerely welcome all guests to set up business relationships with us on the basis of mutual benefits. Please contact us now. You will get our professional reply within 8 hours.
2022 High quality Intermediate Of Allopurinol - ETHYL (ETHOXYMETHYLENE)CYANOACETATE with assay 98% min – MEVA Detail:

1. Hazards identification
Classification of the substance or mixtureClassification according to Regulation (EC) No 1272/2008
H315 Causes skin irritation
H319 Causes serious eye irritation
H335 May cause respiratory irritation
P261 avoid breathing dust/fume/gas/vapours/spray
P305+P351+P338 If in eyes rinse cautiously with water for several minutes. Remove contract lense if present an easy to do-continue rinsing

2. Composition/information on ingredients
Ingredient Name: Ethyl (ethoxymethylene)cyanoacetate
Formula: C8H11NO3
Molecular Weight: 168.18g/mol
CAS: 94-05-3
EC-No: 202-299-5

3. First aid measures
Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance

If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

In case of skin contact
Wash off with soap and plenty of water. Consult a physician.

In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Indication of any immediate medical attention and special treatment needed
No data available

4. Firefighting measures
Extinguishing media

Suitable extinguishing media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Special hazards arising from the substance or mixture
Carbon oxides, nitrogen oxides (NOx)

Advice for firefighters
Wear self contained breathing apparatus for firefighting if necessary.

5. Accidental release measures

Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensureadequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.For personal protection see section 8.

Environmental precautions
Do not let product enter drains.

Methods and materials for containment and cleaning up
Pick up andarrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closedcontainers for disposal.


6.
Handling and storage
Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fireprotection.

Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

Specific end use(s)
A part from the uses mentioned in section 1.2 no other specific uses are stipulated

7. Exposure controls/personal protection
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks andat the end of workday.

Personal protective equipment
Wear laboratory clothing.chemical-resistant gloves and safety goggles

Eye/face protection
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection testedand approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove’s outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices.Wash and dry hands.

Control of environmental exposure
Do not let product enter drains.

8: Physical and chemical properties
Information on basic physical and chemical properties
Appearance: Form: solid
Color: Light yellow
Ordour: not available


Product detail pictures:

2022 High quality Intermediate Of Allopurinol - ETHYL (ETHOXYMETHYLENE)CYANOACETATE with assay 98% min – MEVA detail pictures

2022 High quality Intermediate Of Allopurinol - ETHYL (ETHOXYMETHYLENE)CYANOACETATE with assay 98% min – MEVA detail pictures

2022 High quality Intermediate Of Allopurinol - ETHYL (ETHOXYMETHYLENE)CYANOACETATE with assay 98% min – MEVA detail pictures


Related Product Guide:

"Based on domestic market and expand overseas business" is our improvement strategy for 2022 High quality Intermediate Of Allopurinol - ETHYL (ETHOXYMETHYLENE)CYANOACETATE with assay 98% min – MEVA , The product will supply to all over the world, such as: Estonia, Cairo, Switzerland, We now have been making our goods for more than 20 years . Mainly do wholesale , so we've the most competitive price , but highest quality. For the past years , we got very good feedbacks , not only because we offer good solutions , but also because of our good after-sale service . We are here waiting for yourself for your inquiry.
  • Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Rosalind from Vietnam - 2018.06.18 17:25
    This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Leona from Uzbekistan - 2017.09.29 11:19
    Write your message here and send it to us